Boeing 737 — cold & dark startup
The complete start-up procedure of the B737-800 from an empty cockpit.
Initial power-up
- Battery ON
- Standby power AUTO
- Wait for the ISFD self-test
Electrical power
- Generator switches OFF
- APU switch → START
- Wait for the APU to run (EGT rise, RPM stabilises)
- APU GEN switches ON
IRS alignment
- IRS selectors → NAV (both)
- Wait about 7–10 minutes for the alignment
Hydraulics
- Confirm the engine HYD pumps ON
- Electric HYD pumps ON
FMC programming
- INIT REF page → enter the position, cost index
- RTE page → origin/destination, route
- PERF INIT → ZFW, fuel, reserves
- N1 LIMIT → select the derate
Engine start
- Engine start switch → GRD (usually engine 2 first, per the operator's SOP)
- Monitor the N2 rise and oil pressure
- At ~25% N2 (or maximum motoring) → engine start lever → IDLE
- Monitor the fuel flow, then the EGT rise
- At ~56% N2 the starter cuts out (the switch returns to OFF) — the engine stabilises at idle
- Repeat for the other engine