Lesson 10: Emergency procedures

Simulator: Lekce 10: Nouzové postupy

Emergency procedures

Engine failure after take-off

  1. Below 500 ft AGL — NEVER turn back! Land ahead
  2. Above 1,000 ft AGL — you may turn back if you can make it
  3. Best glide speed (C172: 68 KIAS)
  4. Terrain ahead — choose the best area

Engine failure in flight

  1. Best glide speed
  2. Look for an airfield or a suitable area
  3. Restart attempt: fuel selector BOTH, mixture RICH, carb heat ON, magnetos CHECK
  4. Squawk 7700, Mayday on 121.5 MHz
  5. Secure: fuel OFF, magnetos OFF, master OFF before impact

Engine fire

  1. Mixture — CUT OFF
  2. Fuel — OFF
  3. Master — OFF (unless IFR/night)
  4. Emergency landing IMMEDIATELY